Features and Applications

These cables have good properties of flame retardancy, oil resistance, halogen-free, low temperature resistance, ozone resistance, chemical oil and fuel resistance; Recommended for high temperature applications in railway vehicles (locomotives, trains, trolley buses), used as power and control cables for protected installation inside & outside of rolling stock power, and used in auxillary & main circuit wiring such as control panels, monitoring control, electric heating, lighting etc.

EN 50382 Silicone Insulated 1.8/3kV 3.6/6 kV Rated Type F (150°C) Cable

EN-50382-Silicone-Insulated-Type-F-150°C-Cable-from-Huadong-Cable-Group

  • Voltage: 1.8/3kV
  • Conductor: Annealed Plain Class 5 Copper Conductor as per EN 60228
  • Insulation: silicone rubber with high mechanical properties – type EI 111 as per EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated 1.8/3kV 3.6/6 kV Rated Type F (120°C) Cable

EN-50382-Silicone-Insulated-Type-F-120°C-Cable-from-Huadong-Cable-Group

  • Voltage: 1.8/3kV, 3.6/6 kV
  • Conductor: Annealed Plain Class 5 Copper Conductor as per EN 60228
  • Insulation: silicone rubber with high mechanical properties – type EI 111 as per EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 1.8/3 kV Rated Type FC (120°C) Cable

EN-50382-Silicone-Insulated-Type-FC-150°C-Cable-from-Huadong-Cable-Group

  • Voltage: 1.8/3kV
  • Conductor: Annealed Plain Class 5 Copper Conductor as per EN 60228
  • Insulation: silicone rubber with high mechanical properties – type EI 111 as per EN 50382-1
  • Sheath : EBXL – EM 105 as per BS EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 1.8/3 kV 3.6/6 kV Rated Type FF (150°C) Cable

EN-50382-Silicone-Insulated-and-Sheathed-Type-FF-150°C-Cable-from-Huadong-Cable-Group

  • Voltage: 1.8/3kV, 3.6/6 kV
  • Conductor: Annealed Plain Class 5 Copper Conductor as per EN 60228
  • Insulation: silicone rubber with high mechanical properties – type EI 111 as per EN 50382-1
  • Sheath : silicone rubber with high mechanical properties – type EM 107 as per EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 1.8/3 kV 3.6/6 kV Rated Type FF (120°C) Cable

EN-50382-Silicone-Insulated-and-Sheathed-Type-FF-120°C-Cable-from-Huadong-Cable-Group

  • Voltage: 1.8/3kV, 3.6/6 kV
  • Conductor: Annealed Plain Class 5 Copper Conductor as per EN 60228
  • Insulation: silicone rubber with high mechanical properties – type EI 111 as per EN 50382-1
  • Sheath : silicone rubber with high mechanical properties – type EM 107 as per EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 3.6/6 kV Rated Type FX (150°C) Cable

EN-50382-Silicone-Insulated-and-SheathedType-FX-150°C-Cable-from-Huadong-Cable-Group

  • Voltage: 3.6/6 kV
  • Conductor: Annealed Plain Class 6 Copper Conductor as per EN 60228
  • Insulation: EBXL – EI 111 as per BS EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 3.6/6 kV Rated Type FX (120°C) Cable

EN-50382-Silicone-Insulated-and-SheathedType-FX-120°C-Cable-from-Huadong-Cable-Group

  • Voltage: 3.6/6 kV
  • Conductor: Annealed Plain Class 6 Copper Conductor as per EN 60228
  • Insulation: EBXL – EI 111 as per BS EN 50382-1
  • Colour : As per customer order

EN 50382 Silicone Insulated and Sheathed 3.6/6 kV Rated Type FXZ (120°C) Cable

EN-50382-Silicone-Insulated-and-Sheathed-Type-FXZ-120°C-Cable-from-Huadong-Cable-Group

  • Voltage: 3.6/6 kV
  • Conductor: Conductor : Annealed Tinned Class 6 Copper Conductor as per EN 60228
  • Separator Tape (Optional)
  • Insulation : EBXL – EI 111 as per BS EN 50382-1
  • Braiding: Synthetic Reinforcing Braid within the Insulation

EN 50382 Silicone Insulated and Sheathed 3.6/6 kV Rated Type FXZ (120°C) Cable

EN-50382-Silicone-Insulated-and-Sheathed-Type-FXZ-120°C-Cable-from-Huadong-Cable-Group

  • Voltage: 3.6/6 kV
  • Conductor: Conductor : Annealed Tinned Class 6 Copper Conductor as per EN 60228
  • Separator Tape (Optional)
  • Insulation : EBXL – EI 111 as per BS EN 50382-1
  • Braiding: Synthetic Reinforcing Braid within the Insulation
  • 1.8/3kV Rated Type F (150°C) Cable
  • 1.8/3kV Type F (120°C) Cable
  • 1.8/3kV Type FC (120°C) Cable
  • 1.8/3kV Type FF (150°C) Cable
  • 3.6/6kV Type FX (150°C) Cable
  • 3.6/6kV Type FXZ (120°C) Cable
Nominal Cross- Section Insulation Thickness Nom. Weight(Approx.)
mm2 mm Kg/Km
1.5 2.5 71
2.5 2.5 86
4 2.5 106
6 2.5 131
10 2.5 178
16 2.5 245
25 2.5 340
35 2.5 444
50 2.5 594
70 2.5 792
95 2.7 1058
120 2.7 1300
150 2.7 1585
185 2.7 1915
240 2.7 2432
300 2.7 2967
400 2.9 3864
Nominal Cross- Section Insulation Thickness Nom. Weight(Approx.)
mm2 mm Kg/Km
2.5 3 110
4 3 131
6 3 158
10 3 208
16 3 278
25 3 376
35 3 483
50 3 638
70 3 840
95 3 1085
120 3.1 1339
150 3.1 1627
185 3.2 1972
240 3.4 2522
300 3.4 3060
400 3.4 3931
Nominal Cross- Section Sheath Thickness Nom. Weight (Approx.)
mm2 mm Kg/Km
1.5 1.4 82
2.5 1.4 97
4 1.4 118
6 1.4 144
10 1.4 208
16 1.4 278
25 1.4 396
35 1.4 504
50 1.4 661
70 1.5 884
95 1.5 1171
120 1.6 1433
150 1.6 1729
185 1.7 2119
240 1.8 2672
300 1.9 3229
400 2 4144
Nominal Cross- Section Sheath Thickness Nom. Weight (Approx.)
mm2 mm Kg/Km
1.5 1.4 82
2.5 1.4 97
4 1.4 118
6 1.4 144
10 1.4 208
16 1.4 278
25 1.4 396
35 1.4 504
50 1.4 661
70 1.5 884
95 1.5 1171
120 1.6 1433
150 1.6 1729
185 1.7 2119
240 1.8 2672
300 1.9 3229
400 2 4144
Nominal Cross- Section Insulation Thickness Nom. Weight (Approx.)
mm2 mm Kg/Km
50 3 559
70 3 744
95 3 994
120 3.1 1220
150 3.1 1487
185 3.2 1794
Nominal Cross- Section Insulation Thickness Nom. Weight (Approx.)
mm2 mm Kg/Km
50 3 596
70 3 785
95 3 1012
120 3.1 1260
150 3.1 1519
185 3.2 1840

    PLEASE FEEL FREE TO GIVE YOUR INQUIRY IN THE FORM BELOW

    WE WILL REPLY YOU IN 24 HOURS

    whatapp-icon

      Inquiry

      E-mail: trade@huadongcablegroup.com

        Inquiry

        Email:trade@huadongcablegroup.com

        Name

        Email *

        Whatsapp

        Requirement *

        X