APPLICATION
MV90 cable is mainly used for medium-voltage power distribution in industrial, commercial, and utility applications. It is designed to deliver reliable electrical power from substations to equipment, buildings, and infrastructure systems, and is suitable for installation in cable trays, conduits, and underground networks. MV90 cables are widely applied in factories, mining operations, renewable energy projects, and public infrastructure such as airports and rail systems, where stable and durable power transmission is required.
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Fully annealed bare copper Class B compressed strand (filled or unfilled)
- Gauge Sizes: Available in 2 AWG through 1000kcmil
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Ethylene Propylene Rubber (EPR)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Aluminum 1350 Solid
- Gauge Sizes: Available in 2 AWG through 4/OAWG
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Ethylene Propylene Rubber (EPR)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Class B compressed strand (filled or unfilled)
- Gauge Sizes: Available in 2 AWG through 4/OAWG
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Ethylene Propylene Rubber (EPR)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Fully annealed bare copper Class B compressed strand (filled or unfilled)
- Gauge Sizes: Available in 2 AWG through 1000kcmil
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Tree-Retardant Cross-linked Polyethylene (TR-XLPE)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Aluminum 1350 Class B compressed strand (filled or unfilled)
- Gauge Sizes: Available in 2 AWG through 1000kcmil
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Tree-Retardant Cross-linked Polyethylene (TR-XLPE)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 15kV, 25KV, 35KV
- Conductor: Aluminum 1350 Solid
- Gauge Sizes: Available in 2AWG through 4/0AWG
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Tree-Retardant Cross-linked Polyethylene (TR-XLPE)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Linear Low-Density Polyethylene (LLDPE)
- Voltage Rating Uo/U: 35KV
- Conductor: Aluminum 1350 Class B compressed strand (filled or unfilled)
- Gauge Sizes: Available in 1/0 AWG through 1500 kcmil
- Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor
- Insulation: Tree-Retardant Cross-linked Polyethylene (TR-XLPE)
- Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation
- Neutral: Helically applied, annealed, solid bare copper wires
- Jacket: Cross-Linked Polyethylene (XLPE)
- Voltage Rating Uo/U: 2.4kV (5kv ICEA)
- Conductor: Class B compressed stranded bare copper per ASTM B3 and B8 (tinned copper per ASTM B33 optional)
- Gauge Sizes: Available in 2 AWG through 1000 kcmil
- Conductor Shield: Semi-conducting cross-linked copolymer
- Insulation: Ethylene Propylene Rubber (EPR)
- Overall Jacket: Polyvinyl Chloride (PVC)