Huadong Cable Group‘s marine Cables are proven effective, safe, long-lasting, and reliable in various challenging conditions such as corrosion, moisture, salty water, oil, heat, etc. All cables we designed to meet all product quality and safety requirements such as JIS C3410, IEC 60092, and NEK606 standards. It passed ABS, CCC, UL classifications. Being a professional marine cable manufacturer, Huadong cable can manufacture a wide range of cables for your specific requirements.

Offshore Cable Type Conductor Insulation Screen Amroured Outer Sheath
BU Cable Tinned Copper Class 5 or 2 Mica tape + Halogen Free EPR Non Non low smoke and halogen free
RU Cable EPR Non Non
RFOU Mica tape + Halogen Free EPR TCWB Armored TCWB Armored
BFOU Mica tape + Halogen Free EPR
RFOU(i) Tinned Copper Class 2 EPR individually screened
RFOU(c) EPR collectively screened
BFOU(i) Mica tape + Halogen Free EPR individually screened
BFOU(c) Mica tape + Halogen Free EPR collectively screened

0.6/1kV BFOU P5/P12 Fire Resistant Offshore Power Cable

BFOU-P5-P2

  • Voltage: 0.6/1kV
  • Conductor: Tinned Copper class 2 or 5
  • Insulation Mica tape + Halogen Free EPR
  • 2 conductors ……………………. blue + brown
  • 3 conductors ……………………. brown + black + grey
  • 4 conductors ……………………. brown + black + grey + blue
  • 5 or more conductors ……….white numbered.
  • Filling sheath: Flame retardant and halogen free compound
  • Screen: Tinned annealed copper wire braid
  • Outer sheath: low smoke and halogen free SHF MUD.
  • Applicaiton: BFOU P5/P12 is used for permanent installation in the control circuits and lights and emergency lighting and critical oƋshore units where there are demands for Żre safety.

250V BFOU(c) Fire Resistant Instrument Offshore Cable

BFOUc

  • Voltage: 250V
  • Conductor: Tinned Copper class 2
  • Insulation: Mica tape + Halogen Free EPR
  • Filling sheath: Flame retardant and halogen free compound
  • Collective screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
  • Armoured: Tinned annealed copper wire braid
  • Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, Grey.
  • Applicaiton: BFOU(C) S4/S8 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists.

250V BFOU(i) Fire Resistant Instrument Offshore Cable

BFOUi

  • Voltage: 250V
  • Conductor: Tinned Copper class 2
  • Insulation: Mica tape + Fire resistance EPR
  • Filling sheath: Flame retardant and halogen free compound
  • Screen: Every pair/triple is screened with copper backed polyester tape in contact with a stranded tinned copper drain wire, wrapped with polyester tape.
  • Armoured: Tinned annealed copper wire braid
  • Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, Grey.
  • Applicaiton: BFOU(I) S3/S7 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists

0.6/1kV RFOU P1/P8 Fire Resistant Offshore Power Cable

BFOU-P5-P2

  • Voltage: 0.6/1kV
  • Conductor: Tinned Copper class 2
  • Insulation: Ethylene propylene rubber (EPR)
  • 2 conductors ……………………. blue + brown
  • 3 conductors ……………………. brown + black + grey
  • 4 conductors ……………………. brown + black + grey + blue
  • 5 or more conductors ……….white numbered.
  • Filling sheath: Flame retardant and halogen free compound
  • Screen: Tinned annealed copper wire braid
  • Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound black.
  • Applicaiton: RFOU P1/P8 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems.

250V RFOU(c) Fire Resistant Instrument Offshore Cable

BFOUc

  • Voltage: 250V
  • Conductor: Tinned Copper class 2
  • Insulation: EPR
  • Filling sheath: Flame retardant and halogen free compound
  • Common screen: Pair/triple are laid up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
  • Armoured: Tinned annealed copper wire braid
  • Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, grey.
  • Applicaiton: RFOU(C) S2/S6 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems.

250V RFOU(i) Fire Resistant Instrument Offshore Cable

BFOUi

  • Voltage: 250V
  • Conductor: Tinned Copper class 2
  • Insulation: Ethylene propylene rubber (EPR)
  • Filling sheath: Flame retardant and halogen free compound
  • Screen: Every pair/triple is screened with copper backed polyester tape in contact with a stranded tinned copper drain wire, wrapped with polyester tape.
  • Armoured: Tinned annealed copper wire braid
  • Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, grey.
  • Applicaiton: RFOU(I) S1/S5 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists.

12/20kV RFOU VFD Offshore Cables

RFOU-VFD-Offshore-Cables

  • Voltage: 12/20 kV
  • Conductor: Tinned Copper class 2
  • Conductor Screening: Extruded semi conducting material
  • Insulation: Ethylene propylene rubber (EPR)
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Tape: Copper backed polyester tape ( % 100 coverage )
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free extruded compound, SHFMUD in accordance with NEK TS 606
  • Applicaiton: RFOU VFD is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

8,7/15kV RFOU TYPE P4/P11 Rubber Insulated Offshore Cables

RFOU-TYPE-P19-P21-Rubber-Insulated-Offshore-Cables

  • Voltage: 8,7/15kV
  • Conductor: Tinned Copper class 2
  • Conductor Screening: Extruded semi conducting material
  • Insulation: Ethylene propylene rubber {EPR), IEC 60092-351
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free thermoset compound in accordance with type SHF2, IEC 60092-359
  • Applicaiton: RFOU TYPE P19/P21 is used in fixed for for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

6/10kV RFOU TYPE P3/P10 Rubber Insulated Offshore Cables

RFOU-TYPE-P3-P10-Rubber-Insulated-Offshore-Cables

  • Voltage: 6/10 kV
  • Conductor: Tinned Copper class 2
  • Conductor Screening: Extruded semi conducting material
  • Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
  • Applicaiton: RFOU TYPE P3/P10 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

3,6/6kV BFOU TYPE P6/P13 Rubber Insulated Offshore Cables

BFOU-TYPE-P6-P13-Rubber-Insulated-Offshore-Cables

  • Voltage: 3.6/6 kV
  • Conductor: Tinned Copper class 2
  • Conductor Screening: Extruded semi conducting material
  • Tape: Helically wrapped fire resistant tape
  • Insulation: Ethylene propylene rubber (EPR), IEC 60092-351
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
  • Applicaiton: BFOU TYPE P6/P13 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

3,6/6kV RFOU TYPE P2/P9 Rubber Insulated Cables

RFOU-TYPE-P2-P9-Rubber-Insulated-Cables

  • Voltage: 3.6/6 kV
  • Conductor: Tinned Copper class 2
  • Conductor Screening: Extruded semi conducting material
  • Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
  • Applicaiton: RFOU TYPE P2/P9 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

250V BFCU(C) Screened, Galvanised Steel Wire Braided Cable

BFCUC-Screened-Galvanised-Steel-Wire-Braided-Cable

  • Voltage: 250V
  • Conductor: Plain or Tinned Copper class 2 or
  • Conductor Screening: Extruded semi conducting material
  • Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
  • Insulation Screening: Extruded semi conducting material
  • Insulation Screening: Tape semi conducting material
  • Insulation Screening: Tinned copper wire braid
  • Bedding/Inner covering: Halogen free compound
  • Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
  • Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
  • Applicaiton: BFCU(C) is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
Type-Marine-Cable-Banner
  • BFOU P5/P12 Offshore Cable
  • RFOU P1/P8 Offshore Cable
  • BFOU(c) Instrument Offshore Cable
  • BFOU(i) Instrument Offshore Cable
Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45ºC (A) Voltage drop (V/A·km) Max conduc or resistanc at 20ºC (Ohm/Km)
4G4 17,0 460 34 11,24 50,900
4G6 19,1 650 42 7,48 33,900
4G10 21,5 960 57 4,30 19,500
4G16 24,6 1.4 77 2,74 12,400
4G25 29,0 1.9 100 1,76 0,7950
4G35 32,6 2.25 120 1,25 0,5650
4G50 38,9 3.1 145 0,87 0,3930
4G70 41,2 4 180 0,61 0,2770
4G95 48,0 5.05 225 0,46 0,2100
4G120 52,8 6.3 260 0,36 0,1640
4G150 57,3 7.6 300 0,29 0,1320
4G185 62,7 9 340 0,24 0,1080
4G240 69,4 10.4 400 0,18 0,0817
4 x 1,5/4 15,6 385 18 30,30 137,000
4 x 2,5/6 16,5 440 25 18,10 82,100
4 x 4/6 17,3 480 34 11,24 50,900
4 x 6/6 19,2 680 42 7,48 33,900
4 x 10/10 21,6 1 57 4,30 19,500
4 x 16/16 24,6 1.45 77 2,74 12,400
4 x 25/16 29,0 1.95 100 1,76 0,7950
4 x 35/16 32,6 2.5 120 1,25 0,5650
4 x 50/25 38,9 3.3 145 0,87 0,3930
4 x 70/35 41,2 4.2 180 0,61 0,2770
4 x 95/50 48,0 5.3 225 0,46 0,2100
4 x 120/60 52,8 6.6 260 0,36 0,1640
4 x 150/75 57,3 8 300 0,29 0,1320
Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45ºC (A) Voltage drop (V/A·km) Max conduc or resistanc at 20ºC (Ohm/Km)
4G4 16,77 380 34 11,24 50,900
4G6 18,20 590 42 7,48 33,900
4G10 20,67 880 57 4,30 19,500
4G16 23,28 1.25 77 2,74 12,400
4G25 27,96 1.72 100 1,76 0,7950
4G35 30,82 2.2 120 1,25 0,5650
4G50 36,37 2.9 145 0,87 0,3930
4G70 40,28 3.7 180 0,61 0,2770
4G95 46,44 4.65 225 0,46 0,2100
4G120 50,34 5.7 260 0,36 0,1640
4G150 56,24 7 300 0,29 0,1320
4G185 61,70 8.3 340 0,24 0,1080
4G240 68,99 9.75 400 0,18 0,0817
4 x 1,5/4 14,44 300 18 30,30 137,000
4 x 2,5/6 15,52 340 25 18,10 82,100
4 x 4/6 17,05 400 34 11,24 50,900
4 x 6/6 18,37 610 42 7,48 33,900
4 x 10/10 20,67 900 57 4,30 19,500
4 x 16/16 23,28 1.3 77 2,74 12,400
4 x 25/16 27,96 1.765 100 1,76 0,7950
4 x 35/16 30,82 2.3 120 1,25 0,5650
4 x 50/25 36,37 3 145 0,87 0,3930
4 x 70/35 40,28 3.8 180 0,61 0,2770
4 x 95/50 46,44 4.8 225 0,46 0,2100
4 x 120/60 50,34 20.264 260 0,36 0,1640
Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45ºC (A) Voltage drop (V/A·km) Max conduc or resistanc at 20ºC (Ohm/Km)
1 x 2 x 0,75 11,8 180 17,1 62,5 28,3
2 x 2x 0,75 18,2 375 13,7 62,5 28,3
4 x 2 x 0,75 20,0 460 11,2 62,5 28,3
8 x 2 x 0,75 25,6 600 8,9 62,5 28,3
12 x 2 x 0,75 30,6 730 7,7 62,5 28,3
16 x 2 x 0,75 33,7 1.1 7,0 62,5 28,3
19 x 2 x 0,75 35,4 1.51 6,5 62,5 28,3
24 x 2 x 0,75 41,6 2.05 6,5 62,5 28,3
1 x 2 x 1,5 13,0 230 23,0 32,0 14,5
2 x 2x 1,5 20,4 480 18,4 32,0 14,5
4 x 2 x 1,5 22,1 655 15,0 32,0 14,5
7 x 2 x 1,5 27,5 955 12,4 32,0 14,5
8 x 2 x 1,5 29,0 1.05 12,0 32,0 14,5
12 x 2 x 1,5 33,4 1.25 10,3 32,0 14,5
16 x 2 x 1,5 38,0 1.7 9,4 32,0 14,5
19 x 2 x 1,5 39,8 2.15 9,0 32,0 14,5
24 x 2 x 1,5 46,9 2.7 8,5 32,0 14,5
Cross section (mm2) Inner Diameter (mm) Outer Diameter (mm) Weight (Kg/km) Open Air 45ºC (A) Voltage drop (V/A·km) Max conduc or resistanc at 20ºC (Ohm/Km)
1 x 2 x 0,75 7,5 11,3 170 17,1 62,5 28,3
2 x 2x 0,75 12,7 17,3 355 13,7 62,5 28,3
4 x 2 x 0,75 15,0 19,6 500 11,2 62,5 28,3
8 x 2 x 0,75 19,3 24,3 790 8,9 62,5 28,3
12 x 2 x 0,75 22,6 28,0 1.02 7,7 62,5 28,3
16 x 2 x 0,75 26,4 32,2 1.35 7,0 62,5 28,3
19 x 2 x 0,75 28,5 34,5 1.75 6,5 62,5 28,3
4 x 2 x 0,75 32,0 38,6 2.2 6,5 62,5 28,3
1 x 2 x 1,5 8,5 12,3 210 23,0 32,0 14,5
2 x 2x 1,5 14,1 18,7 440 18,4 32,0 14,5
4 x 2 x 1,5 17,4 22,4 675 15,0 32,0 14,5
7 x 2 x 1,5 19,5 24,5 950 12,4 32,0 14,5
8 x 2 x 1,5 20,3 25,3 1.06 12,0 32,0 14,5
12 x 2 x 1,5 23,9 29,7 1.475 10,3 32,0 14,5
16 x 2 x 1,5 28,0 34,0 1.85 9,4 32,0 14,5
19 x 2 x 1,5 32,0 38,5 2.4 9,0 32,0 14,5
24 x 2 x 1,5 36,5 43,2 3 8,5 32,0 14,5
1 x 3 x 1,5 8,9 12,7 230 23,0 32,0 14,5

For other cable specifications or custom orders, please contact us directly: trade@huadongcablegroup.com