Huadong Cable Group‘s marine Cables are proven effective, safe, long-lasting, and reliable in various challenging conditions such as corrosion, moisture, salty water, oil, heat, etc. All cables we designed to meet all product quality and safety requirements such as JIS C3410, IEC 60092, and NEK606 standards. It passed ABS, CCC, UL classifications. Being a professional marine cable manufacturer, Huadong cable can manufacture a wide range of cables for your specific requirements.
| Offshore Cable Type | Conductor | Insulation | Screen | Amroured | Outer Sheath |
| BU Cable | Tinned Copper Class 5 or 2 | Mica tape + Halogen Free EPR | Non | Non | low smoke and halogen free |
| RU Cable | EPR | Non | Non | ||
| RFOU | Mica tape + Halogen Free EPR | TCWB Armored | TCWB Armored | ||
| BFOU | Mica tape + Halogen Free EPR | ||||
| RFOU(i) | Tinned Copper Class 2 | EPR | individually screened | ||
| RFOU(c) | EPR | collectively screened | |||
| BFOU(i) | Mica tape + Halogen Free EPR | individually screened | |||
| BFOU(c) | Mica tape + Halogen Free EPR | collectively screened |
0.6/1kV BFOU P5/P12 Fire Resistant Offshore Power Cable

- Voltage: 0.6/1kV
- Conductor: Tinned Copper class 2 or 5
- Insulation Mica tape + Halogen Free EPR
- 2 conductors ……………………. blue + brown
- 3 conductors ……………………. brown + black + grey
- 4 conductors ……………………. brown + black + grey + blue
- 5 or more conductors ……….white numbered.
- Filling sheath: Flame retardant and halogen free compound
- Screen: Tinned annealed copper wire braid
- Outer sheath: low smoke and halogen free SHF MUD.
- Applicaiton: BFOU P5/P12 is used for permanent installation in the control circuits and lights and emergency lighting and critical oƋshore units where there are demands for Żre safety.
250V BFOU(c) Fire Resistant Instrument Offshore Cable

- Voltage: 250V
- Conductor: Tinned Copper class 2
- Insulation: Mica tape + Halogen Free EPR
- Filling sheath: Flame retardant and halogen free compound
- Collective screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
- Armoured: Tinned annealed copper wire braid
- Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, Grey.
- Applicaiton: BFOU(C) S4/S8 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists.
250V BFOU(i) Fire Resistant Instrument Offshore Cable

- Voltage: 250V
- Conductor: Tinned Copper class 2
- Insulation: Mica tape + Fire resistance EPR
- Filling sheath: Flame retardant and halogen free compound
- Screen: Every pair/triple is screened with copper backed polyester tape in contact with a stranded tinned copper drain wire, wrapped with polyester tape.
- Armoured: Tinned annealed copper wire braid
- Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, Grey.
- Applicaiton: BFOU(I) S3/S7 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists
0.6/1kV RFOU P1/P8 Fire Resistant Offshore Power Cable

- Voltage: 0.6/1kV
- Conductor: Tinned Copper class 2
- Insulation: Ethylene propylene rubber (EPR)
- 2 conductors ……………………. blue + brown
- 3 conductors ……………………. brown + black + grey
- 4 conductors ……………………. brown + black + grey + blue
- 5 or more conductors ……….white numbered.
- Filling sheath: Flame retardant and halogen free compound
- Screen: Tinned annealed copper wire braid
- Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound black.
- Applicaiton: RFOU P1/P8 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems.
250V RFOU(c) Fire Resistant Instrument Offshore Cable

- Voltage: 250V
- Conductor: Tinned Copper class 2
- Insulation: EPR
- Filling sheath: Flame retardant and halogen free compound
- Common screen: Pair/triple are laid up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
- Armoured: Tinned annealed copper wire braid
- Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, grey.
- Applicaiton: RFOU(C) S2/S6 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems.
250V RFOU(i) Fire Resistant Instrument Offshore Cable

- Voltage: 250V
- Conductor: Tinned Copper class 2
- Insulation: Ethylene propylene rubber (EPR)
- Filling sheath: Flame retardant and halogen free compound
- Screen: Every pair/triple is screened with copper backed polyester tape in contact with a stranded tinned copper drain wire, wrapped with polyester tape.
- Armoured: Tinned annealed copper wire braid
- Outer sheath: Flame retardant, halogen free and mud resistant thermoset compound, grey.
- Applicaiton: RFOU(I) S1/S5 is used in fixed installations for control, instrumentation and telecommunication in both explosion and safe areas, in emergency and critical systems where requirement for fire resistance exists.
12/20kV RFOU VFD Offshore Cables

- Voltage: 12/20 kV
- Conductor: Tinned Copper class 2
- Conductor Screening: Extruded semi conducting material
- Insulation: Ethylene propylene rubber (EPR)
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Tape: Copper backed polyester tape ( % 100 coverage )
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free extruded compound, SHFMUD in accordance with NEK TS 606
- Applicaiton: RFOU VFD is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
8,7/15kV RFOU TYPE P4/P11 Rubber Insulated Offshore Cables

- Voltage: 8,7/15kV
- Conductor: Tinned Copper class 2
- Conductor Screening: Extruded semi conducting material
- Insulation: Ethylene propylene rubber {EPR), IEC 60092-351
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free thermoset compound in accordance with type SHF2, IEC 60092-359
- Applicaiton: RFOU TYPE P19/P21 is used in fixed for for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
6/10kV RFOU TYPE P3/P10 Rubber Insulated Offshore Cables

- Voltage: 6/10 kV
- Conductor: Tinned Copper class 2
- Conductor Screening: Extruded semi conducting material
- Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
- Applicaiton: RFOU TYPE P3/P10 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
3,6/6kV BFOU TYPE P6/P13 Rubber Insulated Offshore Cables

- Voltage: 3.6/6 kV
- Conductor: Tinned Copper class 2
- Conductor Screening: Extruded semi conducting material
- Tape: Helically wrapped fire resistant tape
- Insulation: Ethylene propylene rubber (EPR), IEC 60092-351
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
- Applicaiton: BFOU TYPE P6/P13 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
3,6/6kV RFOU TYPE P2/P9 Rubber Insulated Cables

- Voltage: 3.6/6 kV
- Conductor: Tinned Copper class 2
- Conductor Screening: Extruded semi conducting material
- Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
- Applicaiton: RFOU TYPE P2/P9 is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.
250V BFCU(C) Screened, Galvanised Steel Wire Braided Cable

- Voltage: 250V
- Conductor: Plain or Tinned Copper class 2 or
- Conductor Screening: Extruded semi conducting material
- Insulation: Cross-linked Polyethylene (EPR), IEC 60092-351
- Insulation Screening: Extruded semi conducting material
- Insulation Screening: Tape semi conducting material
- Insulation Screening: Tinned copper wire braid
- Bedding/Inner covering: Halogen free compound
- Braid Armour: Tinned copper wire braid in accordance with IEC 60092-350
- Outer sheath: Halogen free mud resistant thermoset compound in accordance with type SHF Mud, NEK TS 606
- Applicaiton: BFCU(C) is used in fixed for power, control and lighting in both and safe areas, emergency and critical systems offshore applications where requirement for installation in areas exposed to mud and drilling or cleaning fluids. Screened against electromagnetic interferences.

- BFOU P5/P12 Offshore Cable
- RFOU P1/P8 Offshore Cable
- BFOU(c) Instrument Offshore Cable
- BFOU(i) Instrument Offshore Cable
| Cross section (mm2) | Diameter (mm) | Weight (Kg/km) | Open Air 45ºC (A) | Voltage drop (V/A·km) | Max conduc or resistanc at 20ºC (Ohm/Km) |
| 4G4 | 17,0 | 460 | 34 | 11,24 | 50,900 |
| 4G6 | 19,1 | 650 | 42 | 7,48 | 33,900 |
| 4G10 | 21,5 | 960 | 57 | 4,30 | 19,500 |
| 4G16 | 24,6 | 1.4 | 77 | 2,74 | 12,400 |
| 4G25 | 29,0 | 1.9 | 100 | 1,76 | 0,7950 |
| 4G35 | 32,6 | 2.25 | 120 | 1,25 | 0,5650 |
| 4G50 | 38,9 | 3.1 | 145 | 0,87 | 0,3930 |
| 4G70 | 41,2 | 4 | 180 | 0,61 | 0,2770 |
| 4G95 | 48,0 | 5.05 | 225 | 0,46 | 0,2100 |
| 4G120 | 52,8 | 6.3 | 260 | 0,36 | 0,1640 |
| 4G150 | 57,3 | 7.6 | 300 | 0,29 | 0,1320 |
| 4G185 | 62,7 | 9 | 340 | 0,24 | 0,1080 |
| 4G240 | 69,4 | 10.4 | 400 | 0,18 | 0,0817 |
| 4 x 1,5/4 | 15,6 | 385 | 18 | 30,30 | 137,000 |
| 4 x 2,5/6 | 16,5 | 440 | 25 | 18,10 | 82,100 |
| 4 x 4/6 | 17,3 | 480 | 34 | 11,24 | 50,900 |
| 4 x 6/6 | 19,2 | 680 | 42 | 7,48 | 33,900 |
| 4 x 10/10 | 21,6 | 1 | 57 | 4,30 | 19,500 |
| 4 x 16/16 | 24,6 | 1.45 | 77 | 2,74 | 12,400 |
| 4 x 25/16 | 29,0 | 1.95 | 100 | 1,76 | 0,7950 |
| 4 x 35/16 | 32,6 | 2.5 | 120 | 1,25 | 0,5650 |
| 4 x 50/25 | 38,9 | 3.3 | 145 | 0,87 | 0,3930 |
| 4 x 70/35 | 41,2 | 4.2 | 180 | 0,61 | 0,2770 |
| 4 x 95/50 | 48,0 | 5.3 | 225 | 0,46 | 0,2100 |
| 4 x 120/60 | 52,8 | 6.6 | 260 | 0,36 | 0,1640 |
| 4 x 150/75 | 57,3 | 8 | 300 | 0,29 | 0,1320 |
| Cross section (mm2) | Diameter (mm) | Weight (Kg/km) | Open Air 45ºC (A) | Voltage drop (V/A·km) | Max conduc or resistanc at 20ºC (Ohm/Km) |
| 4G4 | 16,77 | 380 | 34 | 11,24 | 50,900 |
| 4G6 | 18,20 | 590 | 42 | 7,48 | 33,900 |
| 4G10 | 20,67 | 880 | 57 | 4,30 | 19,500 |
| 4G16 | 23,28 | 1.25 | 77 | 2,74 | 12,400 |
| 4G25 | 27,96 | 1.72 | 100 | 1,76 | 0,7950 |
| 4G35 | 30,82 | 2.2 | 120 | 1,25 | 0,5650 |
| 4G50 | 36,37 | 2.9 | 145 | 0,87 | 0,3930 |
| 4G70 | 40,28 | 3.7 | 180 | 0,61 | 0,2770 |
| 4G95 | 46,44 | 4.65 | 225 | 0,46 | 0,2100 |
| 4G120 | 50,34 | 5.7 | 260 | 0,36 | 0,1640 |
| 4G150 | 56,24 | 7 | 300 | 0,29 | 0,1320 |
| 4G185 | 61,70 | 8.3 | 340 | 0,24 | 0,1080 |
| 4G240 | 68,99 | 9.75 | 400 | 0,18 | 0,0817 |
| 4 x 1,5/4 | 14,44 | 300 | 18 | 30,30 | 137,000 |
| 4 x 2,5/6 | 15,52 | 340 | 25 | 18,10 | 82,100 |
| 4 x 4/6 | 17,05 | 400 | 34 | 11,24 | 50,900 |
| 4 x 6/6 | 18,37 | 610 | 42 | 7,48 | 33,900 |
| 4 x 10/10 | 20,67 | 900 | 57 | 4,30 | 19,500 |
| 4 x 16/16 | 23,28 | 1.3 | 77 | 2,74 | 12,400 |
| 4 x 25/16 | 27,96 | 1.765 | 100 | 1,76 | 0,7950 |
| 4 x 35/16 | 30,82 | 2.3 | 120 | 1,25 | 0,5650 |
| 4 x 50/25 | 36,37 | 3 | 145 | 0,87 | 0,3930 |
| 4 x 70/35 | 40,28 | 3.8 | 180 | 0,61 | 0,2770 |
| 4 x 95/50 | 46,44 | 4.8 | 225 | 0,46 | 0,2100 |
| 4 x 120/60 | 50,34 | 20.264 | 260 | 0,36 | 0,1640 |
| Cross section (mm2) | Diameter (mm) | Weight (Kg/km) | Open Air 45ºC (A) | Voltage drop (V/A·km) | Max conduc or resistanc at 20ºC (Ohm/Km) |
| 1 x 2 x 0,75 | 11,8 | 180 | 17,1 | 62,5 | 28,3 |
| 2 x 2x 0,75 | 18,2 | 375 | 13,7 | 62,5 | 28,3 |
| 4 x 2 x 0,75 | 20,0 | 460 | 11,2 | 62,5 | 28,3 |
| 8 x 2 x 0,75 | 25,6 | 600 | 8,9 | 62,5 | 28,3 |
| 12 x 2 x 0,75 | 30,6 | 730 | 7,7 | 62,5 | 28,3 |
| 16 x 2 x 0,75 | 33,7 | 1.1 | 7,0 | 62,5 | 28,3 |
| 19 x 2 x 0,75 | 35,4 | 1.51 | 6,5 | 62,5 | 28,3 |
| 24 x 2 x 0,75 | 41,6 | 2.05 | 6,5 | 62,5 | 28,3 |
| 1 x 2 x 1,5 | 13,0 | 230 | 23,0 | 32,0 | 14,5 |
| 2 x 2x 1,5 | 20,4 | 480 | 18,4 | 32,0 | 14,5 |
| 4 x 2 x 1,5 | 22,1 | 655 | 15,0 | 32,0 | 14,5 |
| 7 x 2 x 1,5 | 27,5 | 955 | 12,4 | 32,0 | 14,5 |
| 8 x 2 x 1,5 | 29,0 | 1.05 | 12,0 | 32,0 | 14,5 |
| 12 x 2 x 1,5 | 33,4 | 1.25 | 10,3 | 32,0 | 14,5 |
| 16 x 2 x 1,5 | 38,0 | 1.7 | 9,4 | 32,0 | 14,5 |
| 19 x 2 x 1,5 | 39,8 | 2.15 | 9,0 | 32,0 | 14,5 |
| 24 x 2 x 1,5 | 46,9 | 2.7 | 8,5 | 32,0 | 14,5 |
| Cross section (mm2) | Inner Diameter (mm) | Outer Diameter (mm) | Weight (Kg/km) | Open Air 45ºC (A) | Voltage drop (V/A·km) | Max conduc or resistanc at 20ºC (Ohm/Km) |
| 1 x 2 x 0,75 | 7,5 | 11,3 | 170 | 17,1 | 62,5 | 28,3 |
| 2 x 2x 0,75 | 12,7 | 17,3 | 355 | 13,7 | 62,5 | 28,3 |
| 4 x 2 x 0,75 | 15,0 | 19,6 | 500 | 11,2 | 62,5 | 28,3 |
| 8 x 2 x 0,75 | 19,3 | 24,3 | 790 | 8,9 | 62,5 | 28,3 |
| 12 x 2 x 0,75 | 22,6 | 28,0 | 1.02 | 7,7 | 62,5 | 28,3 |
| 16 x 2 x 0,75 | 26,4 | 32,2 | 1.35 | 7,0 | 62,5 | 28,3 |
| 19 x 2 x 0,75 | 28,5 | 34,5 | 1.75 | 6,5 | 62,5 | 28,3 |
| 4 x 2 x 0,75 | 32,0 | 38,6 | 2.2 | 6,5 | 62,5 | 28,3 |
| 1 x 2 x 1,5 | 8,5 | 12,3 | 210 | 23,0 | 32,0 | 14,5 |
| 2 x 2x 1,5 | 14,1 | 18,7 | 440 | 18,4 | 32,0 | 14,5 |
| 4 x 2 x 1,5 | 17,4 | 22,4 | 675 | 15,0 | 32,0 | 14,5 |
| 7 x 2 x 1,5 | 19,5 | 24,5 | 950 | 12,4 | 32,0 | 14,5 |
| 8 x 2 x 1,5 | 20,3 | 25,3 | 1.06 | 12,0 | 32,0 | 14,5 |
| 12 x 2 x 1,5 | 23,9 | 29,7 | 1.475 | 10,3 | 32,0 | 14,5 |
| 16 x 2 x 1,5 | 28,0 | 34,0 | 1.85 | 9,4 | 32,0 | 14,5 |
| 19 x 2 x 1,5 | 32,0 | 38,5 | 2.4 | 9,0 | 32,0 | 14,5 |
| 24 x 2 x 1,5 | 36,5 | 43,2 | 3 | 8,5 | 32,0 | 14,5 |
| 1 x 3 x 1,5 | 8,9 | 12,7 | 230 | 23,0 | 32,0 | 14,5 |
For other cable specifications or custom orders, please contact us directly: trade@huadongcablegroup.com